Saunagen PH-I Bedienerhandbuch Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
Warnings
1. Safety precautions
a. To avoid fire, do not dry clothes or leave any towels in the sauna.
b. To prevent burns or electric shocks, do not touch or use metal tools on the net cover of the far infrared heater
elements.
c. While in the sauna, do not touch the light bulb. If the bulb needs to be changed, switch it off and wait until the
sauna is shut off and the bulb is cool
d. Do not spray water on the far-infrared tube. This activity may result in electric shock or damage to the heater
elements.
e. Do not use the SaunaGen infrared sauna if you have any of the following conditions:
1. Open wounds
2. Eye diseases
3. Sever sunburns
4. Elderly & weak people, especially those suffering from a disease, pregnant women and infants are
prohibited. Children over the age of 6 years may use the sauna under the supervision of adults.
5. If suffering from a disease directly related to temperature, seek the advice of a doctor before using.
6. Do not place pets in the sauna.
7. Do not use the sauna if you are under the effects of alcohol.
Trouble Shooting:
Problem Possible Causes What To Do
The connector is not connected
properly
Check the connector or replace a new
one
1 Indicator light for power
supply not working
The fuse is burned out Change the fuse
The corresponding indicator light is
broken
Replace the relevant control panel 2 Indicator light for function
is not working
The circuit board or components are
broken
Replace the circuit board
The heater is broken
Its life will be shorted gradually for
being used for many times
Replace with a new one
Of the same specifications
The fuse is burned out:
L-Hand fuse holder: For back panel
R-Hand fuse holder: For front panel
Replace with a new one of the same
specifications
The wire junction is loose or the
heater’s wire is loose
Check it, and reconnect them tightly
3 Infrared Heater not
heating up
The circuit board relay is not
functioning
Replace circuit board
11